top of page

Equipment Technology Rental

ETR — Equipment Technology Rental

HVAC & Cooling Rental in Saudi Arabia

Temporary HVAC, package units, air handling units and portable evaporative cooling planned around the application, site conditions and verified technical requirements.

Home / Equipment / HVAC & Cooling Rental

Plan temporary cooling around the space and the project

Temporary cooling is not a single-unit decision. The intended use, occupied area, heat conditions, ventilation, air distribution, humidity and available power interfaces all shape the project discussion.

Service-specific applications and project considerations

Temporary project cooling

Cooling support can be planned for temporary buildings, work areas, commercial spaces and project environments according to the intended use and site conditions.

Industrial and warehouse environments

Large or operational spaces require attention to heat conditions, airflow paths, operating schedules and the way conditioned air will reach the required zones.

Fresh-air and ventilation support

Cooling and ventilation arrangements may incorporate fresh-air requirements where the verified application and site plan call for them.

Ducted air distribution

Packaged or central cooling arrangements may be coordinated with suitable ducted distribution, including fabric air duct solutions where applicable.

Events and temporary structures

Temporary venues and covered spaces need cooling planned with occupancy, opening periods, structure layout, power and air distribution in view.

Humidity and supporting systems

Industrial dehumidification, temporary power, distribution boards and maintenance support may be considered when they form part of the same verified requirement.

More equipment and services

Include related equipment and supporting systems in the same project enquiry where useful.

Related equipment and project solutions

ETR can consider connected equipment and support requirements together where they are relevant to the project scope.

Related project evidence

Hilton Hotels Jeddah — Package Unit Rental

Temporary package-unit rental provided in Jeddah to support project cooling requirements.

Equipment and services are combined only where they are relevant to the project requirement.

Applications and industries

Service planning considers the intended application, operating environment and site requirements.

Equipment and temporary solutions for requirements across these sectors and project environments.

Construction environments

Warehouses and logistics spaces

Events and temporary facilities

Construction & Infrastructure

Industrial & Manufacturing

Events & Exhibitions

Warehousing & Logistics

Commercial Facilities

Contact ETR for project-specific requirements and available configurations.

Project support across Saudi Arabia

Operational locations in Jeddah and Riyadh. Project support across Saudi Arabia is subject to project requirements, logistics, technical requirements, site conditions, rental duration and equipment availability.

Jeddah — Operational location

Riyadh — Operational location

Review Saudi Arabia project coverage

Portacool & Portable Evaporative Coolers

ETR provides 36-inch and 48-inch Portacool size categories for suitable portable evaporative-cooling applications. Portacool equipment is evaporative cooling, not refrigerant-based air conditioning.

Portable Evaporative Cooler

Portacool 36-inch

Approved ETR size category. The actual model and configuration depend on the available unit and project requirements.

Portable Evaporative Cooler

Portacool 48-inch

Approved ETR size category. The actual model and configuration depend on the available unit and project requirements.

Model, CFM, coverage, water consumption and electrical requirements are not inferred from fan diameter alone.

Package Unit Cooling Capacities

ETR provides packaged and fresh-air packaged cooling units across a range of cooling capacities for temporary project applications. The table below summarizes the currently approved fleet capacity data. Electrical values such as running current, MCA and electrical input are shown only when verified from unit-specific data.

PCU: Packaged Air Conditioning Unit. FPCU: Fresh Air Packaged Conditioning Unit. TR: Ton of Refrigeration. Cooling capacity in kW means thermal cooling capacity, not electrical power consumption.

CapacityTypeThermal Cooling CapacityRefrigerant*Voltage*PhaseFrequencyApprox. Air Flow**
5 TRPCU17.6 kW R22 / R407C220 / 380 V3 Ph60 Hz~2,000 CFM
10 TRPCU35.2 kW R22 / R407C220 / 380 V3 Ph60 Hz~4,000 CFM
15 TRPCU52.8 kW R22 / R407C220 / 380 V3 Ph60 Hz~6,000 CFM
20 TRPCU70.3 kW R22 / R407C220 / 380 V3 Ph60 Hz~8,000 CFM
25 TRPCU87.9 kW R22 / R407C220 / 380 V3 Ph60 Hz~10,000 CFM
30 TRPCU105.5 kW R22 / R407C220 / 380 V3 Ph60 Hz~12,000 CFM
50 TRFPCU175.8 kW R22 / R407C220 / 380 V3 Ph60 HzDesign-dependent
60 TRPCU211 kW R22 / R407C220 / 380 V3 Ph60 Hz~24,000 CFM
100 TRFPCU351.7 kW R22 / R407C460 V3 Ph60 HzDesign-dependent
120 TRFPCU422 kW R22 / R407C460 V3 Ph60 HzDesign-dependent

5 TR

PCU

Thermal Cooling Capacity
17.6 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~2,000 CFM
Phase & Frequency
3 Ph • 60 Hz

10 TR

PCU

Thermal Cooling Capacity
35.2 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~4,000 CFM
Phase & Frequency
3 Ph • 60 Hz

15 TR

PCU

Thermal Cooling Capacity
52.8 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~6,000 CFM
Phase & Frequency
3 Ph • 60 Hz

20 TR

PCU

Thermal Cooling Capacity
70.3 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~8,000 CFM
Phase & Frequency
3 Ph • 60 Hz

25 TR

PCU

Thermal Cooling Capacity
87.9 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~10,000 CFM
Phase & Frequency
3 Ph • 60 Hz

30 TR

PCU

Thermal Cooling Capacity
105.5 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~12,000 CFM
Phase & Frequency
3 Ph • 60 Hz

50 TR

FPCU

Thermal Cooling Capacity
175.8 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
Design-dependent
Phase & Frequency
3 Ph • 60 Hz

60 TR

PCU

Thermal Cooling Capacity
211 kW
Voltage*
220 / 380 V
Refrigerant*
R22 / R407C
Air Flow**
~24,000 CFM
Phase & Frequency
3 Ph • 60 Hz

100 TR

FPCU

Thermal Cooling Capacity
351.7 kW
Voltage*
460 V
Refrigerant*
R22 / R407C
Air Flow**
Design-dependent
Phase & Frequency
3 Ph • 60 Hz

120 TR

FPCU

Thermal Cooling Capacity
422 kW
Voltage*
460 V
Refrigerant*
R22 / R407C
Air Flow**
Design-dependent
Phase & Frequency
3 Ph • 60 Hz

* Refrigerant configurations in the approved fleet data include R22 and R407C. The actual refrigerant depends on the specific unit. Available voltage configurations vary by unit.

** Approximate planning value based on 400 CFM/TR for PCU entries only. Actual airflow depends on the specific unit and operating configuration. FPCU airflow is not calculated using this rule; it is design-dependent.

Verified Unit Electrical Data

These cards show only electrical values supported by unit-specific evidence. Running current and electrical input are not inferred from MCA.

Nameplate-verified data

PETRA PPHC 360

380 V • 3 Phase • 60 Hz

R407C

MCA: 116 A

Nameplate-verified data

PETRA PPHC 450

380 V • 3 Phase • 60 Hz

R407C

MCA: 136.6 A

Air Handling Unit (AHU) Capacities

Temporary air handling units can support chilled-water and air-distribution applications when coordinated with the cooling system and site requirements. The CFM values below are planning estimates based on approximately 400 CFM/TR, not verified manufacturer ratings.

CapacityEstimated AirflowData Status
20 TR~8,000 CFMPlanning estimate — configuration-dependent
40 TR~16,000 CFMPlanning estimate — configuration-dependent
60 TR~24,000 CFMPlanning estimate — configuration-dependent
100 TR~40,000 CFMPlanning estimate — configuration-dependent
200 TR~80,000 CFMPlanning estimate — configuration-dependent

20 TR

Chilled Water AHU

Estimated airflow: ~8,000 CFM

Configuration-dependent planning value, not a manufacturer rating.

40 TR

Chilled Water AHU

Estimated airflow: ~16,000 CFM

Configuration-dependent planning value, not a manufacturer rating.

60 TR

Chilled Water AHU

Estimated airflow: ~24,000 CFM

Configuration-dependent planning value, not a manufacturer rating.

100 TR

Chilled Water AHU

Estimated airflow: ~40,000 CFM

Configuration-dependent planning value, not a manufacturer rating.

200 TR

Chilled Water AHU

Estimated airflow: ~80,000 CFM

Configuration-dependent planning value, not a manufacturer rating.

* Actual airflow depends on the unit, coils, fans, static pressure and operating configuration. Unit-specific data must be confirmed before project selection.

Information for Temporary HVAC Selection

Share the project location, space and application, fresh-air requirements, site conditions, operating schedule, available power, air-distribution requirements and expected duration so the appropriate configuration can be reviewed. You can also review air-cooled chiller rental and fabric air duct solutions.

HVAC & Cooling Rental questions

What information is needed to assess temporary cooling?

Share the space type and occupied area, intended use, operating schedule, known heat or humidity conditions, ventilation needs, available power information and site access.

How are package units, AHUs and portable cooling options compared?

Selection starts with the application and site interfaces. Package units, AHUs and portable evaporative-cooling categories serve different arrangements; verified project data is required before confirming equipment.

Are published airflow values manufacturer ratings?

Not always. PCU airflow shown by ETR is an engineering estimate based on approximately 400 CFM per TR and is labelled as approximate. Unit-specific nameplate data takes precedence when available.

Can cooling, air distribution and temporary power be planned together?

Yes, where the project requires connected cooling, fabric air distribution, generators, cables or distribution boards. Each component must still be defined in the project scope.

How is an HVAC rental quotation prepared?

A quotation is prepared from the equipment type and capacity, quantity, rental period, project location, transport, installation requirements, required accessories and technical-support scope.

Request a project-specific cooling discussion

Share the project location, intended application, quantities, required dates, expected rental duration and verified site or technical requirements.

You can also contact ETR directly.

info@etrental.com

Call +966 55 864 5511

WhatsApp ETR

bottom of page